O. Reg. 475/00: FIRE CODE, Filed August 21, 2000 under Fire Protection and Prevention Act, 1997, S.O. 1997, c. 4
ONTARIO REGULATION 475/00
made under the
fire protection and prevention act, 1997
Made: August 18, 2000
Filed: August 21, 2000
Amending O. Reg. 388/97
(Fire Code)
1.鈥(1)鈥俆able 1.1.7.A. of 澳门永利 Regulation 388/97 is amended by striking out 鈥淣FPA 16鈥1995, NFPA 86鈥1995 and CAN/ULC鈥揝643鈥揗90鈥 and substituting the following:
听
Issuing Agency |
Document Number |
Title of Document |
Code Reference |
NFPA |
16鈥1999 |
Foam鈥揥ater Sprinkler and Foam鈥揥ater Spray Systems |
4.8.4.3. (4) |
听 |
听 |
听 |
听 |
听 |
听 |
. . . . . |
听 |
NFPA |
86鈥1995 |
Ovens and Furnaces |
4.4.9.5. (2) |
听 |
听 |
. . . . . |
听 |
ULC |
CAN/ULC鈥揝643鈥揗90 |
Shop Fabricated Steel Aboveground Utility Tanks for Flammable and Combustible Liquids |
1.1.7.3. (2) |
(2)鈥俆able 1.1.7.A. of the Regulation is amended by adding the following:
听
Issuing Agency |
Document Number |
Title of Document |
Code Reference |
UL |
ULI 1275鈥1994 |
Flammable Liquid Storage Cabinets |
4.2.10.5. |
ULC |
ULC鈥揝655鈥98 |
Aboveground Protected Tank Assemblies for Flammable and Combustible Liquids |
4.3.1.2.(1) |
(3)鈥俆able 1.1.7.A. of the Regulation is amended by striking out ULC/ORD鈥揅142.16鈥1994.
2.鈥侫rticle 1.1.7.3. of the Regulation is revoked and the following substituted:
1.1.7.3.(1)鈥侫 reference in this Code to a document listed in Table 1.1.7.A. includes all amendments up to and including April 30, 1997.
(2)鈥侱espite Sentence (1), CAN/ULC鈥揝643鈥揗90, 鈥淪hop Fabricated Steel Aboveground Utility Tanks for Flammable and Combustible Liquids鈥, includes all amendments up to and including June 30, 1998.
3.鈥侫rticle 1.3.1.1. of the Regulation is amended by adding the following abbreviations:
听
UL |
Underwriters Laboratories Inc. |
4.鈥侰lause 4.1.1.3.(1)(b) of the Regulation is amended by striking out 鈥4.8.4.4.鈥.
5.鈥係entences 4.1.1.4.(1) and (2) of the Regulation are revoked and the following substituted:
Compliance schedule
4.1.1.4.(1)鈥侳or existing facilities, the requirements of Articles 4.1.5.7., 4.1.5.9., 4.1.6.1., 4.1.6.2., 4.1.7.1., 4.1.7.2., 4.1.7.3., 4.1.7.4., 4.1.7.5., 4.1.7.6., 4.1.7.7., 4.1.8.3., 4.1.8.4., 4.2.3.3., 4.2.3.4., 4.2.4.1., 4.2.4.2., 4.2.4.3., 4.2.4.5., 4.2.4.6., 4.2.7.1., 4.2.7.2., 4.2.7.3., 4.2.7.4., 4.2.7.5., 4.2.7.6., 4.2.7.7., 4.2.7.13., 4.2.9.1., 4.2.9.2., 4.2.9.3., 4.2.9.5., 4.2.9.6., 4.2.9.8., 4.2.10.1., 4.2.10.2., 4.2.10.3., 4.2.10.5. 4.3.16.2. and 4.6.4.5., Subsections 4.2.1., 4.2.5., 4.2.6., 4.2.8., 4.2.11., 4.3.1., 4.3.4., 4.3.5., 4.3.6., 4.3.10., 4.4.6. (except Articles 4.4.6.3. and 4.4.6.7.), 4.12.2., 4.12.3., 4.12.8. and 4.12.9., and Sections 4.5 (except Articles 4.5.10.1. and 4.5.10.2.) and 4.7 (except Articles 4.7.6.1. and 4.7.6.2.), come into force on August 21, 2000.
(2)鈥侳or existing facilities, the requirements of Articles 4.3.2.4., 4.3.2.5., Subsections 4.3.3., 4.3.7., 4.3.8. (except Sentence 4.3.8.1.(2) and Article 4.3.8.2.), 4.3.9., 4.3.11., 4.3.12., 4.3.13. and 4.3.14., and Sections 4.4 (except Subsections 4.4.11. and 4.4.6. and Article 4.4.9.5.), 4.6 (except Articles 4.6.4.2., 4.6.4.5. and 4.6.5.1.), 4.8 and 4.9 (except Article 4.9.8.1.), come into force on August 21, 2002.
6.鈥侫rticle 4.1.5.9. of the Regulation is revoked and the following substituted:
Basement storage
4.1.5.9.(1)鈥侲xcept as permitted in Sentences (2), (3) and (4), Class I liquids shall not be stored, handled or used in basements or pits.
(2)鈥侰lass I liquids may be stored in dwelling units as described in Article 4.2.4.5. and mercantile occupancies as described in Sentence 4.2.5.2.(3).
(3)鈥俇p to 5 L of Class I liquids may be stored in basements, provided it is stored in safety containers conforming to ULC/ORD鈥揅30, 鈥淪afety Containers鈥.
(4)鈥侰lass I liquids not exceeding 250 L in quantity may be stored, handled or used in existing laboratories described in Subsection 4.12.1. where
(a) continuous mechanical ventilation is provided to ensure that flammable vapour concentrations do not exceed 25 per cent of the lower explosive limit in the basement or pit,
(b) the continuous mechanical ventilation required in Clause (a) sounds an audible alarm in an attended area upon shut down of the ventilation system,
(c) the Class I liquids are located in a fire compartment separated from the rest of the building by a fire separation having a 1鈥揾r fire-resistance rating,
(d) despite Article 4.1.5.6., the building has a fire safety plan in conformance with Section 2.8,
(e) Class IA liquids are not stored in containers greater than 4 L in capacity,
(f) except where all dispensing of Class I liquids is carried out in a power ventilated enclosure in conformance with Articles 4.12.8.3. to 4.12.8.5. and where Class IA liquids are stored in storage cabinets in conformance with Article 4.2.10.5., the room is designed to prevent critical structural and mechanical damage from internal explosion in conformance with NFPA 68, 鈥淕uide for Venting of Deflagrations鈥, and
(g) except where all sources of ignition within 0.9 m from the floor are eliminated, the room is provided with a flammable vapour detection system that will alarm in an attended location upon detection of vapour concentrations exceeding 10 per cent of the lower explosive limit.
(5)鈥侱espite Clause (4)(c), existing fire separations consisting of lath and plaster or gypsum board shall be deemed to be in compliance with Clause (4)(c).
7.鈥侫rticle 4.1.6.1. of the Regulation is revoked and the following substituted:
Spill control
4.1.6.1.(1)鈥侫 spill of flammable or combustible liquids shall be prevented from reaching waterways, sewer systems and potable water sources by
(a) a barrier of noncombustible construction of sufficient capacity to contain the spill, or
(b) grading the site or sloping the floor to divert the spill to a drainage system conforming to Article 4.1.6.2.
(2)鈥俉here barriers required in Sentence (1) are provided to contain accidental spillage from aboveground storage tanks, they shall conform to the requirements for secondary containment in Subsection 4.3.7.
(3)鈥俆he fire safety plan required in Article 4.1.5.6. shall include measures to be taken to direct overflow of spilled liquids and fire fighting water away from
(a) buildings,
(b) isolation valves controlling processes or fire protection systems,
(c) a means of egress,
(d) adjoining property,
(e) fire department access routes, and
(f) a water supply used for fire fighting.
8.鈥侫rticle 4.2.7.2. of the Regulation is amended by adding 鈥(1)鈥 after 鈥4.2.7.2.鈥.
9.鈥侫rticle 4.2.7.7. of the Regulation is revoked and the following substituted:
Fire suppression systems
4.2.7.7.(1)鈥俉here protection is required by this Part, storage areas for flammable and combustible liquids shall be
(a) sprinklered in conformance with NFPA 30, 鈥淔lammable and Combustible Liquids Code鈥, or
(b) protected by an automatic fire suppression system in conformance with an applicable standard listed in Sentence 6.8.1.1.(1).
10.鈥侰lause 4.2.8.4.(4)(c) of the Regulation is amended by striking out 鈥淐lass III鈥 and substituting 鈥淐lass IIIA鈥.
11.鈥係entences 4.2.9.6.(1) and (2) are amended by striking out 鈥済ood engineering practice such as described in鈥 after 鈥渋n conformance with鈥 in each case.
12.鈥侫rticle 4.2.10.5. of the Regulation is revoked and the following substituted:
Storage cabinets
4.2.10.5.(1)鈥係torage cabinets required in this Part shall
(a) conform to ULC鈥揅1275, 鈥淪torage Cabinets for Flammable Liquid Containers鈥,
(b) conform to ULI 1275, 鈥淔lammable Liquid Storage Cabinets鈥,
(c) be Factory Mutual Research Approved, or
(d) be listed as meeting NFPA 30.
13.鈥係entence 4.3.1.2.(1) of the Regulation is revoked and the following substituted:
(1)鈥侲xcept as required in Sentences (2), (4), (6) and (8) and permitted in Sentences (3), (5) and (7) and in Section 4.9, atmospheric storage tanks shall be built in conformance with
(a) API 12B, 鈥淏olted Tanks for Storage of Production Liquids鈥,
(b) API 12D, 鈥淔ield Welded Tanks for Storage of Production Liquids鈥,
(c) API 12F, 鈥淪hop Welded Tanks for Storage of Production Liquids鈥,
(d) API 650, 鈥淲elded Steel Tanks for Oil Storage鈥,
(e) ULC鈥揝601, 鈥淪hop Fabricated Steel Aboveground Horizontal Tanks for Flammable and Combustible Liquids鈥,
(f) CAN/ULC鈥揝602, 鈥淎boveground Steel Tanks for Fuel Oil and Lubricating Oil鈥,
(g) CAN/ULC鈥揝603, 鈥淪teel Underground Tanks for Flammable and Combustible Liquids鈥,
(h) CAN/ULC鈥揝603.1, 鈥淕alvanic Corrosion Protection Systems for Steel Underground Tanks for Flammable and Combustible Liquids,鈥
(i) CAN4鈥揝615, 鈥淩einforced Plastic Underground Tanks for Petroleum Products鈥,
(j) ULC鈥揝630, 鈥淪hop Fabricated Steel Aboveground Vertical Tanks for Flammable and Combustible Liquids鈥,
(k) CAN/ULC鈥揝643, 鈥淪hop Fabricated Steel Aboveground Utility Tanks for Flammable and Combustible Liquids鈥,
(l) ULC鈥揝652, 鈥淭ank Assemblies for Collection of Used Oil鈥,
(m) ULC鈥揝653, 鈥淎boveground Steel Contained Tank Assemblies for Flammable and Combustible Liquids鈥,
(n) ULC/ORD鈥揅58.10, 鈥淛acketed Steel Underground Tanks for Flammable and Combustible Liquids鈥,
(o) ULC/ORD鈥揅142.5, 鈥淐oncrete Encased Steel Aboveground Tank Assemblies for Flammable and Combustible Liquids鈥,
(p) ULC鈥揝655, 鈥淎boveground Protected Tank Assemblies for Flammable and Combustible Liquids鈥, or
(q) ULC/ORD鈥揅142.23, 鈥淎boveground Waste Oil Tanks鈥.
14.鈥侫rticle 4.3.1.2. is amended by adding the following Sentences:
(5)鈥侲xisting aboveground atmospheric storage tanks in service that do not comply with Sentence (1) are permitted to remain in service provided that the tank
(a) is not leaking,
(b) has no dents in the tank greater than 30 degrees or 35 mm in depth from the normal configuration,
(c) has no pitting in excess of 3 mm, and
(d) has metal thickness of at least 50 per cent of the minimum permissible thickness specified in an applicable standard referenced in Sentence (1).
(6)鈥侲xisting aboveground atmospheric storage tanks that do not comply with Sentence (1), (3), (5) or (9) shall be refurbished in conformance with Sentence 4.10.4.2.(3) or be replaced.
(7)鈥侲xisting underground storage tanks in service that do not comply with Sentence (1) are permitted to remain in service provided that the tanks are not leaking and steel storage tanks and associated piping are protected from external corrosion in conformance with Subsection 4.3.9.
(8)鈥侲xisting underground storage tanks that do not comply with Sentence (1), (3) or (7) shall be refurbished in conformance with Sentence 4.10.4.2.(3) or be replaced.
(9)鈥侲xisting aboveground atmospheric storage tanks that comply to ULC/ORD鈥揅142.16鈥1994, 鈥淧rotected Aboveground Tank Assemblies for Flammable and Combustible Liquids鈥 shall be deemed to comply with Clause (1)(p).
15.鈥侰lause 4.3.2.1.(7)(a) of the Regulation is amended by striking out 鈥淯LC/ORD鈥揅142.16, 鈥淧rotected Aboveground Tank Assemblies for Flammable and Combustible Liquids鈥濃 and substituting 鈥淯LC鈥揝655, 鈥淎boveground Protected Tank Assemblies for Flammable and Combustible Liquids鈥濃.
16.鈥係ubclause 4.3.7.4.(2)(a)(ii) of the Regulation is amended by striking out 鈥4.3.1.2.(1)(e) or (j)鈥 and substituting 鈥4.3.1.2.(1)(e), (j) or (k)鈥.
17.鈥侰lause 4.3.9.1.(2)(b) of the Regulation is amended by striking out 鈥淐atholic鈥 and substituting 鈥淐athodic鈥.
18.鈥侫rticle 4.3.13.3. of the Regulation is amended by striking out 鈥済ood engineering practice such as described in鈥 after 鈥渋n conformance with鈥.
19.鈥係entence 4.3.13.4.(1) of the Regulation is revoked and the following substituted:
(1)听鈥侷n buildings not required to be equipped with a standpipe system by the Building Code, hose stations conforming to Articles 3.2.9.2. to 3.2.9.7. of 澳门永利 Regulation 403/97 (1997 澳门永利 Building Code) shall be provided in the vicinity of the storage room, such that all parts of the room are within reach of a hose stream.
20.鈥侫rticle 4.4.5.5. of the Regulation is amended by striking out 鈥渙f 650掳C and above without damage鈥 and substituting 鈥渙f at least 650掳C without damage that would impair its function鈥.
21.鈥(1)鈥係entence 4.4.8.1.(1) of the Regulation is amended by striking out 鈥淪entences (2) and (3)鈥 and substituting 鈥淪entences (2), (3) and (4)鈥.
(2)鈥侫rticle 4.4.8.1 of the Regulation is amended by adding the following Sentence:
(4)鈥侲xisting valves shall be deemed to comply with Sentences (1), (2) and (3), provided they are
(a) not leaking, and
(b) constructed of material that is in conformance with Article 4.4.2.1.
22.鈥侫rticle 4.4.9.5. of the Regulation is revoked and the following substituted:
4.4.9.5.(1)鈥侲xcept as permitted in Sentence (2), the use of open flames as a heat source shall not be permitted for heating piping for flammable or combustible liquids.
(2)鈥俇se of open flames shall be permitted for heating piping for flammable or combustible liquids, when such operations are carried out in furnaces or ovens conforming to NFPA 86, 鈥淥vens and Furnaces鈥.
23.鈥係entence 4.4.10.6.(3) of the Regulation is amended by striking out 鈥淪entence (1)鈥 and substituting 鈥淪entence (2)鈥.
24.鈥侫rticle 4.5.8.7. of the Regulation is revoked and the following substituted:
Sources of ignition
4.5.8.7.鈥係moking or any other source of ignition shall not be permitted within 3 m of a dispenser at a fuel dispensing station.
25.鈥係entence 4.6.4.5.(1) of the Regulation is amended by inserting 鈥渟hall be鈥 after 鈥渢ank cars鈥.
26.鈥侰lause 4.7.11.4.(1)(b) of the Regulation is revoked and the following substituted:
(b) unless the cargo hose is equipped with a device that prevents liquid from draining from the hose, it shall be drained into appropriate containers that shall be emptied in such a fashion as to not create a fire or explosion hazard.
27.鈥侫rticle 4.8.3.1. is amended by striking out 鈥済ood engineering practice such as described in鈥 after 鈥渋n conformance with鈥.
28.鈥侫rticle 4.8.3.3. of the Regulation is revoked and the following substituted:
4.8.3.3.(1)鈥侲xcept as permitted in Article 4.1.5.9., Class I liquids shall not be handled or used in basements.
(2)鈥俉here Class I liquids are handled or used above grade within existing buildings that have basements or covered pits into which flammable vapours can travel and accumulate, such below grade areas shall be provided with mechanical ventilation designed to prevent the accumulation of flammable vapours.
(3)鈥俆he mechanical ventilation required in Sentence (2) shall be capable of exhausting at least 18 m3/hr per square metre of the room area.
29.鈥係entences 4.9.3.2.(2) and (3) of the Regulation are amended by striking out 鈥淪ection 6.8鈥 and substituting in each case 鈥渁n applicable standard listed in Sentence 6.8.1.1.(1)鈥.
30.鈥侰lause 4.12.8.4.(2)(b) of the Regulation is amended by striking out 鈥淪ection 6.8鈥 and substituting 鈥渁n applicable standard listed in Sentence 6.8.1.1.(1)鈥.
31.鈥係entence 4.12.8.5.(3) of the Regulation is amended by striking out 鈥淪ection 6.8鈥 and substituting 鈥渁n applicable standard listed in Sentence 6.8.1.1.(1)鈥.
32.鈥侰lause 6.8.1.1.(1)(g) of the Regulation is amended by striking out 鈥淒eluge鈥 before 鈥淔oam鈥揥ater Sprinkler鈥.
听
David H. Tsubouchi
Solicitor General
Dated on August 18, 2000.